Lintels & Windposts
HWP Windposts are used in combination with suitable wall ties, to restrain brickwork walls against wind pressure and suction. The windposts are made from specially designed channels that have welded plates with slotted holes in order to be easily and securely fixed on to the reinforced concrete beams.
Lintels & Windposts
HWP Windposts are used in combination with suitable wall ties, to restrain brickwork walls against wind pressure and suction. The windposts are made from specially designed channels that have welded plates with slotted holes in order to be easily and securely fixed on to the reinforced concrete beams.
The windposts can be specially designed and manufac- tured suitable to withstand the wind loads on the project. The span distances of the channels may be arranged according to the structural integrity and the restrictions of the construction. Structural analysis must be made in view of these limitations. Applications and load requirements can be specifically designed and structural analyses prepared according to the specifications of the project.
Windposts
HWP Windposts are used in combination with suitable wall ties to restrain brickwork walls against wind pressure and suction.
The windposts are made from specially designed channels with welded plates that feature slotted holes, allowing for easy and secure fixation onto reinforced concrete beams.
HMLS Lintels
HMLS Lintels are used to support brick cladding above openings in walls.
In combination with suitable wall ties, they help restrain brickwork walls against wind pressure and suction. The windposts are made from specially designed channels with welded plates featuring slotted holes, allowing for easy and secure fixation onto reinforced concrete beams.
Windposts can be custom-designed and manufactured to withstand project-specific wind loads. The span distances of the channels can be arranged based on structural integrity and construction constraints. Structural analysis must be conducted to account for these factors. Applications and load requirements can be tailored, with structural analyses prepared according to project specifications.
HMLS-T Lintel Support
Concealed Fixing: A custom-designed steel component is used in combination with slotted hole plates to support bricks with reinforcement bars.
Minimum Bearing: The steel component must have a minimum bearing of 150 mm on the wall surface.
Custom Design: The system can be tailored to fit various application requirements, ensuring flexibility in construction projects.